A QINGDAO ZONGDA product-series websiteMINE AIRFLOW • TECHNICAL SELECTION
K45 mine fan series — Representative mine fan image from the supplied technical presentation; not a dimensioned photograph of every listed variant.
Representative mine fan image from the supplied technical presentation; not a dimensioned photograph of every listed variant.

K45 mine fan series

K45 Mine Ventilation Fan Manufacturer

A mine fan series presented separately from K40, with its own size, speed, airflow and total-pressure combinations.

Discuss configuration, documentation and delivery terms directly with ZONGDA.

SPECIFICATION REVIEW

K45 mine fan series reference data

Published reference configuration
SeriesK45
Application basisMetal/non-coal mine ventilation
Pressure basisTotal pressure
Selection basisRequired airflow and pressure; selected performance curve
Ranges in the table do not describe every possible airflow/pressure combination. Obtain the selected performance curve. The supplied K/DK material does not establish explosion-protected coal-mine suitability.

APPLICATION & PROCUREMENT

Review the working task

K45 mine ventilation fan supplier comparisons should use the exact series and selected configuration, with a ZONGDA quotation tied to your project's airflow and pressure requirement. K45 is presented separately from K40 in the supplied technical documentation. A familiar motor rating or similar model name is not enough to treat the two series as interchangeable.

The reference data includes K45-4 No. 10 at 1450 rpm with a 30 kW motor, airflow of 13.0–24.0 m³/s and total pressure of 558–1071 Pa. A separate K45-6 No. 12 entry lists 980 rpm, 18.5 kW, 15.1–28.5 m³/s and 367–704 Pa. These figures help identify catalogue entries for discussion; they don't define a guaranteed operating point or a complete supply package.

Include in your inquiry

  • Required airflow and pressure basis
  • Air density or altitude and temperature
  • Supply voltage, installation and noise constraints
Prepare Model Inquiry

Configuration and selection

Keep K45 in the request for quotation, followed by the size and speed if already selected. If you're still comparing candidates, provide the required airflow and pressure instead of choosing whichever row has the largest numbers. Ask the proposed curve to identify the selected configuration and the conditions on which the selection is based.

Pressure terminology matters. K45 catalogue values are total pressure, while your design brief may state a different basis. Keep that distinction visible in the comparison. The duty-point guide explains what to include in the inquiry. For general background, the U.S. Department of Energy's fan system sourcebook describes fan curves as a relationship between airflow, pressure and required power. It does not provide product-specific approval or performance verification for this series.

Application requirements

The source presentation places the K/DK range in metal and other non-coal mine ventilation. It discusses main-fan and auxiliary-fan roles, with surface and underground installations. State which role your project requires and let the technical review establish whether the offered K45 configuration meets it. A broad application label cannot replace that review.

Suppose you're comparing a K45 proposal with an existing fan. Include the available outline and connection information, installation constraints and the required duty from your project team. Ask for differences to be identified before price comparison. For a main-fan or station-fan request, include diffuser scope in the discussion because the technical presentation specifically addresses supporting diffusers. The purpose here is to define what needs quoting, not to prescribe an installation or operating procedure.

Supplier quotation and scope of supply

Make the commercial comparison easy to audit. Each K45 offer should name the model, machine number, speed, motor and selected performance curve. Ask the manufacturer for dimensions, electrical requirements and the proposed connection arrangement as part of the technical submission. Request clarification wherever a quotation references only a family brochure.

  • Provide airflow with units and the required pressure basis.
  • Include altitude or air density, temperature and available electrical supply.
  • Describe space restrictions and any project noise requirements.
  • State quantity, destination and the documents required by your purchasing process.

Ask the supplier to separate the fan assembly, diffuser and any other offered items so that inclusions are visible. Obtain a current factory quotation and delivery terms for that scope; catalogue data alone does not establish either. Review K40 reference configurations if the project team wants an alternative, then prepare a K45 quotation request with the same duty and evaluation criteria.

K45 mine fan series procurement FAQ

Is K45 simply another name for K40?

No. The supplied presentation has separate series tables. Keep the exact series in the inquiry and compare the chosen entries using their own curves, speeds and motor specifications.

Can I select K45 by motor power alone?

Motor power is one part of the specification. Ask for the airflow and pressure duty on the selected curve, together with the size, speed and applicable conditions, before accepting a proposed match.

Do the table ranges guarantee every airflow and pressure combination?

No. A range table does not establish all combinations within its limits. The selected curve is needed to assess a particular airflow and pressure together.

What information helps obtain a comparable price?

Send a common technical brief to each supplier and ask for clearly listed inclusions, exclusions and documents. Check that competing offers refer to the same duty, pressure basis and assembly scope before treating their prices as comparable.

Ordering and after-sales support

Can I discuss a different fan specification?

ZONGDA accepts specification-customization requests. Submit the required airflow, pressure basis, electrical supply and installation constraints for technical review. Ask the offer to identify the accepted fan configuration and its curve; customization availability is not proof that an arbitrary duty point can be met.

What order timing should a ventilation project allow?

ZONGDA publishes a usual general order cycle of one to two months, with expedited production and occasional stock also mentioned. The selected fan size, motor and delivery destination still need a current schedule. Ask about availability early when coordinating the fan with other site work.

What installation and after-sales assistance is available?

The company describes installation and commissioning services, spare-parts supply, and online and local technical after-sales support. Identify the installation location and assistance required in your inquiry. Agree the service scope and applicable warranty terms for the fan package; the published information does not specify a universal warranty duration.

Payment, delivery and service arrangements

Discuss This Order

SERIES REFERENCE

Representative performance-table entries

Selected K45 mine fan series entries
Model / sizeSpeed (r/min)Motor rating (kW)Airflow (m³/s)Total pressure (Pa)
K45-4 / No. 1014503013.0–24.0558–1071
K45-4 / No. 15145020043.9–82.61256–2409
K45-6 / No. 1298018.515.1–28.5367–704

These are source-table ranges, not guaranteed operating points. Ask for the curve at the proposed size, speed, setting and site conditions.

Source document and next checks

Read the original supplied technical document alongside these selected reference figures. Confirm the current revision and configuration in your quotation.

Open original technical file (DOCX)

SPECIFY YOUR REQUIREMENT

Bring the operating conditions.
Request the right configuration.

Include airflow, total pressure, installation, quantity and delivery destination in your inquiry.

Request a Technical Quote