A QINGDAO ZONGDA product-series websiteMINE AIRFLOW • TECHNICAL SELECTION
K40 mine fan series — Representative mine fan image from the supplied technical presentation; not a dimensioned photograph of every listed variant.
Representative mine fan image from the supplied technical presentation; not a dimensioned photograph of every listed variant.

K40 mine fan series

K40 Mine Ventilation Fan Manufacturer

A mine fan series with representative K40-4, K40-6 and K40-8 entries from the supplied technical presentation.

Discuss configuration, documentation and delivery terms directly with ZONGDA.

SPECIFICATION REVIEW

K40 mine fan series reference data

Published reference configuration
SeriesK40
Application basisMetal/non-coal mine ventilation
Pressure basisTotal pressure
Selection basisRequired airflow and pressure; selected performance curve
Ranges in the table do not describe every possible airflow/pressure combination. Obtain the selected performance curve. The supplied K/DK material does not establish explosion-protected coal-mine suitability.

APPLICATION & PROCUREMENT

Review the working task

K40 mine ventilation fan supplier inquiries should identify the required duty as well as the series name when requesting a ZONGDA quotation. The supplied technical presentation lists K40-4, K40-6 and K40-8 entries with different sizes, speeds and motor ratings. That gives a buyer several reference configurations to investigate, rather than a single fan specification that fits every installation.

For example, the technical documentation lists K40-4 No. 8 at 1450 rpm with a 5.5 kW motor, an airflow range of 4.4–9.5 m³/s and a total-pressure range of 108–497 Pa. K40-6 No. 16 is listed at 980 rpm and 55 kW. These are catalogue references. A quotation needs to identify the actual configuration and its selected performance curve.

Include in your inquiry

  • Required airflow and pressure basis
  • Air density or altitude and temperature
  • Supply voltage, installation and noise constraints
Prepare Model Inquiry

Configuration and selection

Start with the airflow and pressure supplied by your project ventilation designer. Keep the units visible, and state whether the required pressure is static or total. The K40 reference table reports total pressure; changing that label to static pressure would change the meaning of the figures. Nor can the upper airflow value and upper pressure value be assumed to occur together.

Send altitude or air-density information, temperature and the intended installation arrangement with the inquiry. The U.S. Department of Energy's fan system sourcebook identifies airflow, pressure, air properties and layout as inputs to fan selection. This is general selection context, not a test report for K40. Use the fan duty-point guide to organize your request, then ask for the curve matching the proposed size, speed and blade setting.

Application requirements

The supplied K/DK presentation describes the range primarily for metal and other non-coal mines, with main-fan and auxiliary-fan applications and surface or underground installation. Those family descriptions provide an application starting point. They don't establish that every listed K40 configuration is suitable for your location or installation.

For a replacement inquiry, include the existing fan identification, available drawings and the required duty from the current project brief. For a new installation, describe the intended fan role and available space. Ask the proposal to identify the diffuser and connection arrangement: the source document discusses dedicated diffusers for main-fan and station-fan service. Have the project team review the offered assembly against the installation requirements. This product page supplies procurement information rather than a mine ventilation design.

Supplier quotation and scope of supply

A useful K40 price request asks for an identifiable package. List the series, proposed quantity, project destination, electrical supply and documents needed for evaluation. If you haven't selected a size, say so and submit the duty requirements. Naming only a motor rating can leave the supplier quoting a different configuration from the one your engineer intended.

  • Ask the manufacturer for the model, machine number, speed and selected curve together.
  • Ask which motor, diffuser, connections and other components are included.
  • Request outline dimensions and the information needed to review the electrical interface.
  • Ask for a current factory quotation, delivery terms, documentation and separately identified options.

Compare offers on that shared scope before comparing totals. The K45 series page provides another catalogue reference, but similar power does not prove equivalent performance. When your brief is ready, prepare a K40 inquiry and ask ZONGDA to confirm the proposed configuration in writing.

K40 mine fan series procurement FAQ

Can I order K40 using only the series name?

The name is enough to start a conversation, but not to define the supplied fan. Include the required airflow, pressure basis and site conditions, then request a size, speed, motor and matching curve in the offer.

Are the published pressure values static pressure?

No. The reference table uses total pressure. If your project specification gives static pressure, retain that description in the inquiry and ask for a selection on the correct basis.

Does the maximum airflow apply at maximum pressure?

The ranges do not establish that combination. Review the selected performance curve and ask the supplier to identify the proposed duty point rather than combining separate limits from the table.

What should a replacement-fan inquiry include?

Send the existing equipment details, available connection drawings, electrical supply and the required duty. Ask for any differences between the existing assembly and the proposed K40 package to be listed explicitly.

Ordering and after-sales support

Can I discuss a different fan specification?

ZONGDA accepts specification-customization requests. Submit the required airflow, pressure basis, electrical supply and installation constraints for technical review. Ask the offer to identify the accepted fan configuration and its curve; customization availability is not proof that an arbitrary duty point can be met.

What order timing should a ventilation project allow?

ZONGDA publishes a usual general order cycle of one to two months, with expedited production and occasional stock also mentioned. The selected fan size, motor and delivery destination still need a current schedule. Ask about availability early when coordinating the fan with other site work.

What installation and after-sales assistance is available?

The company describes installation and commissioning services, spare-parts supply, and online and local technical after-sales support. Identify the installation location and assistance required in your inquiry. Agree the service scope and applicable warranty terms for the fan package; the published information does not specify a universal warranty duration.

Payment, delivery and service arrangements

Discuss This Order

SERIES REFERENCE

Representative performance-table entries

Selected K40 mine fan series entries
Model / sizeSpeed (r/min)Motor rating (kW)Airflow (m³/s)Total pressure (Pa)
K40-4 / No. 814505.54.4–9.5108–497
K40-6 / No. 169805523.6–51.4197–908
K40-8 / No. 207307534.3–74.7170–787

These are source-table ranges, not guaranteed operating points. Ask for the curve at the proposed size, speed, setting and site conditions.

Source document and next checks

Read the original supplied technical document alongside these selected reference figures. Confirm the current revision and configuration in your quotation.

Open original technical file (DOCX)

SPECIFY YOUR REQUIREMENT

Bring the operating conditions.
Request the right configuration.

Include airflow, total pressure, installation, quantity and delivery destination in your inquiry.

Request a Technical Quote