DK40 mine fan series reference data

Published reference configuration
SeriesDK40
Application basisMetal/non-coal mine ventilation
Pressure basisTotal pressure
Selection basisRequired airflow and pressure; selected performance curve
Ranges in the table do not describe every possible airflow/pressure combination. Obtain the selected performance curve. The supplied K/DK material does not establish explosion-protected coal-mine suitability.

APPLICATION & PROCUREMENT

Review the working task

DK40 mine ventilation fan supplier inquiries need to preserve the paired motor ratings shown in the ZONGDA technical presentation. This series is listed with entries such as 2 × 37 kW, rather than a single 37 kW motor. Keeping that notation intact helps purchasing and engineering teams discuss the same proposed assembly.

For reference, DK40-6 No. 15 is listed at 980 rpm with 2 × 37 kW, airflow of 18.2–43.6 m³/s and total pressure of 382–1690 Pa. The DK40-8 No. 18 entry also lists 2 × 37 kW, but at 730 rpm with different airflow and pressure ranges. Matching motor ratings therefore do not make these entries equivalent. Request a configuration-specific quotation and the corresponding curve.

Include in your inquiry

  • Required airflow and pressure basis
  • Air density or altitude and temperature
  • Supply voltage, installation and noise constraints
Prepare Model Inquiry

Configuration and selection

Ask the offer to identify the complete DK40 model, machine number, speed and motor arrangement. The paired rating is a documented specification, but it does not by itself explain the electrical connections or operating arrangement of the assembly being offered. Obtain those details from the supplier instead of deriving them from the letters in the series name.

Provide required airflow, required pressure and its static or total basis. The catalogue table reports total pressure, and its ranges do not guarantee every possible combination of airflow and pressure. Use the duty-point checklist to assemble the brief. The U.S. Department of Energy's fan system sourcebook identifies air properties and system layout among the inputs to selection. Include those conditions in your request; the publication is general background and does not validate DK40 performance.

Application requirements

The supplied K/DK material describes metal and other non-coal mine ventilation, including main-fan and auxiliary-fan service. It also discusses surface and underground installation. Tell ZONGDA the intended role, location and constraints so the proposed DK40 assembly can be reviewed against a specific brief.

Installation scope deserves its own line in the inquiry. The source presentation discusses dedicated diffusers for main-fan and station-fan applications, so ask which diffuser and connection arrangement accompanies the proposal. Request the assembly outline and interface information needed by the project team. Do not infer dimensions from a representative product image. Where access or space is limited, supply the available layout rather than asking the supplier to assume a standard installation. Final suitability depends on the documented selection and project review.

Supplier quotation and scope of supply

A DK40 price comparison can become misleading if one offer describes the complete assembly while another omits components. Request a clearly itemized scope showing the fan, both listed motors, diffuser where proposed, electrical items and supporting documentation. Ask the manufacturer to distinguish included equipment from items that the project must provide.

  • Keep the paired motor notation in the technical and commercial schedules.
  • Supply voltage and frequency details for electrical review.
  • Request the selected performance curve and its stated conditions.
  • List quantity, destination and any required technical submission documents.

Obtain current commercial terms after the proposed scope is clear. Ask about delivery, packing, spare-parts recommendations and documentation as quotation questions, with the response recorded in the offer. If comparing another series, use the K45 product information as a separate reference and retain the same project duty. Prepare a DK40 inquiry with the available drawings and requirements so missing details can be identified early.

DK40 mine fan series procurement FAQ

What does 2 × 37 kW mean in the DK40 table?

The source lists a paired motor rating. Preserve both motors in your request and ask for the proposed assembly's electrical and operating arrangement. Do not shorten the entry to a single 37 kW motor.

Are DK40 entries with the same paired rating interchangeable?

No. The reference entries can have different speeds and performance ranges despite matching motor ratings. Compare the full model and selected curve against the required duty.

Can the catalogue table confirm my operating point?

It provides reference ranges, not every paired airflow and pressure value. Request a curve for the selected configuration and confirmation of the point proposed for your conditions.

Is a diffuser automatically included in the price?

The technical presentation discusses dedicated diffusers, but the catalogue does not define an individual quotation's supply scope. Ask the offer to identify the diffuser, connections and any excluded installation items explicitly.

Ordering and after-sales support

Can I discuss a different fan specification?

ZONGDA accepts specification-customization requests. Submit the required airflow, pressure basis, electrical supply and installation constraints for technical review. Ask the offer to identify the accepted fan configuration and its curve; customization availability is not proof that an arbitrary duty point can be met.

What order timing should a ventilation project allow?

ZONGDA publishes a usual general order cycle of one to two months, with expedited production and occasional stock also mentioned. The selected fan size, motor and delivery destination still need a current schedule. Ask about availability early when coordinating the fan with other site work.

What installation and after-sales assistance is available?

The company describes installation and commissioning services, spare-parts supply, and online and local technical after-sales support. Identify the installation location and assistance required in your inquiry. Agree the service scope and applicable warranty terms for the fan package; the published information does not specify a universal warranty duration.

Payment, delivery and service arrangements

Discuss This Order

SERIES REFERENCE

Representative performance-table entries

Selected DK40 mine fan series entries
Model / sizeSpeed (r/min)Motor rating (kW)Airflow (m³/s)Total pressure (Pa)
DK40-6 / No. 159802 × 3718.2–43.6382–1690
DK40-6 / No. 209802 × 16043.2–103.4680–3004
DK40-8 / No. 187302 × 3723.5–56.1306–1350

These are source-table ranges, not guaranteed operating points. Ask for the curve at the proposed size, speed, setting and site conditions.

Source document and next checks

Read the original supplied technical document alongside these selected reference figures. Confirm the current revision and configuration in your quotation.

Open original technical file (DOCX)

SPECIFY YOUR REQUIREMENT

Bring the operating conditions.
Request the right configuration.

Include airflow, total pressure, installation, quantity and delivery destination in your inquiry.

Request a Technical Quote